Zimmer ATS 750 Automatic Tourniquet System – Certified Refurbished
$522.00
Details:
Condition: Certified Refurbished
Warranty: 90 Days
- Uses electronic and microprocessor-regulated pressure
- 30-minute battery backup provides mobility by helping ensure continuous power
- Visual and audible alarms are activated when an unsafe condition is detected
- Uses ambient air
Contact the Manufacturer
MFR: Zimmer
hone: (800) 830-0970
The Zimmer ATS 750 Automatic Tourniquet System (#60-0750-101-00) includes tubing, a new internal battery, and power cord.
Warranty: 90 Days – Parts and Labor.
Zimmer Tourniquet systems offer built-in proprietary safety features as recommended by the association of periOperative Registered Nurses.
- Self-check calibration automatically checks the accuracy of the machine calibration each time the unit is powered on.
- Cuff alert notifies user of cuff status when attempt is made to set the machine to stand-by.
- Cuff lockout feature prompts the user to confirm the deflation command during bilateral or IVRA procedure in order to reduce complications due to sudden cuff deflation of the second cuff.
- Dimensions: 7.9″ (D) x 7″ (W) x 8″ (H) (20.1 cm x 17.8 cm x 20.3 cm).
- Weight: 7.7 lb (3.5 kg).
- Timer:
- Time Alarm Set Ranges: 5 to 240 minutes; 5 minutes increments.
- Timer Accuracy: 0.25% of elapsed time.
- Power:
- Line Voltage Range: 100 to 240 VAC, 50/60 Hz, Auto Switching.
- Line Current: 670 mA RMS @ 120 VAC.
- Input Power: 53 Watts Typical.
- Power Cord: Type SJT, AWG 16, 14 ft (4.27 m).
- Power Plug: Hospital grade, 3 prong straight blade, 15 Amp.
- Pressure:
- Cuff Pressure Range: 50 to 475 mmHg, 5 mmHg increments.
- Pressure Accuracy: +/- 5 mmHg (50 to 475 mmHg).
- Pressure Regulation: +/- 6 mmHg of set point (10 second average under non-transient conditions without external leaks).
- Maximum Pressures: 475 mmHg cuffs.
- Battery:
- Battery Type: Rechargeable, 12 VDC sealed lead acid, 1.2 Amp hours.
- Battery Discharge Time: Unit will operate on battery power for 30 minutes minimum with fully charge batteries.
- Battery Recharge Time: 24 hours (Maximum) Unit should be plugged in 24 hours before initial use.
- Uses ambient air.
- Uses electronic and microprocessor regulated pressure.
- Single Port System: Uses single port, single bladder cuff.
- 30 minute battery back-up provides mobility by helping ensure continuous power.
- Visual and audible alarms activated when an unsafe condition is detected.
- Self-check calibration each time the A.T.S. 750 System is switched on.
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “Zimmer ATS 750 Automatic Tourniquet System – Certified Refurbished” Cancel reply
Reviews
Clear filtersThere are no reviews yet.