Hamilton T1 Transport Ventilator

Details:

CALL US FOR THE BEST PRICE

Full-featured ventilator designed for transport situations.

The Hamilton T1 is the first high-end ventilator designed for the unique needs of transport situations. With advanced features and a durable construction, the Hamilton T1 Transport Ventilator performs like a full featured intensive care ventilator while reliably accompanying patients in mobile environments. The onboard, high-performance blower allows the ventilator to operate independently from compressed air, reducing weight and saving space during transport.  
  • State-of-the-art transport ventilator delivers the same performance as a full-featured ICU, PICU, or NICU ventilator.
  • Designed specifically for transport environments.
  • Reliable respiratory therapy in transport situations for all patient groups, from adults to neonates.
  • Wide range of ventilation modes:
    • Closed-loop control: ASV
    • Pressure: PCV+, PSIMV+, SPONT, APRV, DuoPAP
    • Volume: (S)CMV+/APVcmv, SIMV+/APVsimv
    • Noninvasive: NIV, NIV-ST, nCPAP, nCPAP-PC
  • Independence from gas supply and compressor.
  • Tidal volumes range from 20 ml to 2,000 ml.
  • Rated for more than 9 hours of battery life, extended with hot-swappable batteries.
  • Water-resistant, shock-resistant housing.
  • Anti-reflective display.
  • Optional: Neonatal tidal volume from 2 ml to 300 ml.

Ventilation Modes

  • Closed-loop control: ASV
  • Pressure: PCV+, PSIMV+, SPONT, APRV, DuoPAP
  • Volume: (S)CMV+/APVcmv, SIMV+/APVsimv
  • Noninvasive: NIV, NIV-ST, nCPAP, nCPAP-PC

Physical Dimensions

  • Height (with handle raised): 11.8 in
  • Height (with handle lowered): 9.4 in
  • Width: 12.2 in
  • Depth: 8.3 in
  • Mobile Stand Height: 53.5 in
  • Mobile Stand Width: 24.8 in
  • Weight: 14.3 lb (with one battery and handle) | 12.3 lb (without battery or handle)
  • Display: 8.4 in, TFT, color, backlit, touchscreen, night-vision compatibility
  • Main Patient Outlet: ISO 5356-1; 22M/15F
  • Oxygen Inlet: DISS or NIST male
  • Low Oxygen Inlet: CPC quick coupling, 3.2 mm ID

Environment

  • Operating Temperature: -15°C to 50°C (adult) / -15°C to 40°C (neonatal)
  • Operating Humidity: 5% to 95% non-condensing
  • Altitude: Up to approx. 25,000 ft, 1,000 to 376 hPa (adults), 13,120 ft, 1,000 to 600 hPa (neonates)
  • Storage Temperature: -20°C to 60°C
  • Storage Humidity: 10% to 95% non-condensing
0 reviews