Full-featured ventilator designed for transport situations.
The Hamilton T1 is the first high-end ventilator designed for the unique needs of transport situations. With advanced features and a durable construction, the Hamilton T1 Transport Ventilator performs like a full featured intensive care ventilator while reliably accompanying patients in mobile environments. The onboard, high-performance blower allows the ventilator to operate independently from compressed air, reducing weight and saving space during transport.- State-of-the-art transport ventilator delivers the same performance as a full-featured ICU, PICU, or NICU ventilator.
- Designed specifically for transport environments.
- Reliable respiratory therapy in transport situations for all patient groups, from adults to neonates.
- Wide range of ventilation modes:
- Closed-loop control: ASV
- Pressure: PCV+, PSIMV+, SPONT, APRV, DuoPAP
- Volume: (S)CMV+/APVcmv, SIMV+/APVsimv
- Noninvasive: NIV, NIV-ST, nCPAP, nCPAP-PC
- Independence from gas supply and compressor.
- Tidal volumes range from 20 ml to 2,000 ml.
- Rated for more than 9 hours of battery life, extended with hot-swappable batteries.
- Water-resistant, shock-resistant housing.
- Anti-reflective display.
- Optional: Neonatal tidal volume from 2 ml to 300 ml.
Ventilation Modes
- Closed-loop control: ASV
- Pressure: PCV+, PSIMV+, SPONT, APRV, DuoPAP
- Volume: (S)CMV+/APVcmv, SIMV+/APVsimv
- Noninvasive: NIV, NIV-ST, nCPAP, nCPAP-PC
Physical Dimensions
- Height (with handle raised): 11.8 in
- Height (with handle lowered): 9.4 in
- Width: 12.2 in
- Depth: 8.3 in
- Mobile Stand Height: 53.5 in
- Mobile Stand Width: 24.8 in
- Weight: 14.3 lb (with one battery and handle) | 12.3 lb (without battery or handle)
- Display: 8.4 in, TFT, color, backlit, touchscreen, night-vision compatibility
- Main Patient Outlet: ISO 5356-1; 22M/15F
- Oxygen Inlet: DISS or NIST male
- Low Oxygen Inlet: CPC quick coupling, 3.2 mm ID
Environment
- Operating Temperature: -15°C to 50°C (adult) / -15°C to 40°C (neonatal)
- Operating Humidity: 5% to 95% non-condensing
- Altitude: Up to approx. 25,000 ft, 1,000 to 376 hPa (adults), 13,120 ft, 1,000 to 600 hPa (neonates)
- Storage Temperature: -20°C to 60°C
- Storage Humidity: 10% to 95% non-condensing
Rated 0 out of 5